Aller au contenu principal

Philips Satinelle Tension Clip Replacement

Ce dont vous avez besoin

  1. Philips Satinelle Tension Clip Replacement, Tension Clip Replacement: étape 1, image 1 de 1
    • Remove Tweezer Head by pushing to the left with thumb.

  2. Philips Satinelle Tension Clip Replacement: étape 2, image 1 de 3 Philips Satinelle Tension Clip Replacement: étape 2, image 2 de 3 Philips Satinelle Tension Clip Replacement: étape 2, image 3 de 3
    • Locate the Tension Clip on the removable tweezer head.

    • Begin prying from the right side of the Tension Clip.

    • Finish removal by prying the left side of the Tension Clip.

  3. Philips Satinelle Tension Clip Replacement: étape 3, image 1 de 3 Philips Satinelle Tension Clip Replacement: étape 3, image 2 de 3 Philips Satinelle Tension Clip Replacement: étape 3, image 3 de 3
    • Replace the Tension Clip

    • Insert left side of clip roughly half way in.

    • Insert right side of clip and push both sides down with thumbs.

  4. Philips Satinelle Tension Clip Replacement: étape 4, image 1 de 2 Philips Satinelle Tension Clip Replacement: étape 4, image 2 de 2
    • Use Opening Tool to fully depress Tension Clip in place.

Conclusion

Contact the manufacturer for a replacement Tension Clip.

To reassemble your device, follow these instructions in reverse order.