Introduction

Use for a diagnosed wiring problem.

Pièces

Aucune pièce nécessaire.

Using a Torx T20 screwdriver, remove the four screws attaching the back plate. Using a Torx T20 screwdriver, remove the four screws attaching the back plate.
  • Using a Torx T20 screwdriver, remove the four screws attaching the back plate.

Ajouter un commentaire

Remove the five screws attaching the drill handle.
  • Remove the five screws attaching the drill handle.

Ajouter un commentaire

Remove the 4 screws attaching the front of the casing. Remove the 4 screws attaching the front of the casing.
  • Remove the 4 screws attaching the front of the casing.

Ajouter un commentaire

Use a multimeter set above 18V DC to check electrical connections where wires meet drill, switch, or battery terminal.
  • Use a multimeter set above 18V DC to check electrical connections where wires meet drill, switch, or battery terminal.

Ajouter un commentaire

Look for corrosion or burnt wires.
  • Look for corrosion or burnt wires.

  • If there are any bad connections or if there is visible damage, replace damaged wire and solder.

Ajouter un commentaire

  • After soldering sand off jaged solder then wrap with electrical tape

Ajouter un commentaire

Conclusion

To reassemble your device, follow these instructions in reverse order.

Une autre personne a terminé cette réparation.

Evan Long

Membre depuis le 15/04/2010

232 Réputation

4 tutoriels rédigés

Équipe

Cal Poly, Team 15-48, Garner Spring 2010 Membre de l'équipe Cal Poly, Team 15-48, Garner Spring 2010

CPSU-GARNER-S10S15G48

6 membres

5 tutoriels rédigés

Ajouter un commentaire

Voir les statistiques:

Dernières 24 heures : 1

7 derniers jours : 7

30 derniers jours : 34

Total : 3,949