Contribution d'origine par : Mark
Texte:
The usual problem with this kettle is that the relay stops working. Even though the relay makes the clicking sound but once you remove it and test it you'll see that the switch doesn't close. The Part number is NT75-1A. You can replace it with an American made relay that should last longer.
Statut: