  1. Keurig K70 Top  Needle Replacement, Handle: étape 1, image 1 de 2 Keurig K70 Top  Needle Replacement, Handle: étape 1, image 2 de 2
    • Locate the handle on top of the unit

    • Locate the two Torx head screws on the underside of the handle. Remove them with a T15 screwdriver

  2. Keurig K70 Top  Needle Replacement: étape 2, image 1 de 3 Keurig K70 Top  Needle Replacement: étape 2, image 2 de 3 Keurig K70 Top  Needle Replacement: étape 2, image 3 de 3
    • Bend the handle outward to remove

  3. Keurig K70 Top  Needle Replacement, Top  Needle: étape 3, image 1 de 1
    • While looking upwards from underneath the Keurig, remove the two 8mm Phillips #2 screws from underneath the black plastic "shroud".

    • Remove the black plastic "shroud" by pushing inwards and then pulling upwards to disengage the plastic hooks that are not visible.

  4. Keurig K70 Top  Needle Replacement: étape 4, image 1 de 3 Keurig K70 Top  Needle Replacement: étape 4, image 2 de 3 Keurig K70 Top  Needle Replacement: étape 4, image 3 de 3
    • Remove the two 8 mm screws with a PH #1 screwdrver

    • Pull on the plastic tube to remove it

    • This will require a generous amount of force

  5. Keurig K70 Top  Needle Replacement: étape 5, image 1 de 1
    • Remove the two 8mm screws with a PH #2 screwdriver.

  6. Keurig K70 Top  Needle Replacement: étape 6, image 1 de 1
    • Pull out on the top component perpendicular to the top face as shown. It will pop out without too much effort.

    • The needle is now exposed on the bottom of the part being handled in this photo. Be careful where you grab this component, we recommend doing as we have done here. Grab the front "lip" of the component (see photo).

  7. Keurig K70 Top  Needle Replacement: étape 7, image 1 de 1
    • This is the component that should detach after pulling down.

    • Be careful of the needle!

  8. Keurig K70 Top  Needle Replacement: étape 8, image 1 de 1
    • On the bottom of the component is the exposed needle, which is now accessible.

    • If you remove the needle be careful as it may be sharp.

Conclusion

To reassemble your device, follow these instructions in reverse order.

2 autres ont terminé cette réparation.

Alec Foster

Membre depuis le 10/06/16

161 Réputation

1 tutoriel rédigé

Équipe

Cal Poly, Team 20-4, Livingston Fall 2016 Membre de l'équipe Cal Poly, Team 20-4, Livingston Fall 2016

CPSU-LIVINGSTON-F16S20G4

4 membres

5 tutoriels rédigés

2 commentaires

If the needle were sharp this wouldn’t be necessary.

Can a replacement ‘needle’ be purchased somewhere? This must be almost universal and should be easily obtainable from Keurig.

krrjr49 - Réponse

Did you find a place to purchase a replacement top needle? All I can find is the bottom exit needle assembly.

Liz Mark - Réponse

Ajouter un commentaire

Nombre de vues :

Dernières 24 heures : 2

7 derniers jours : 8

30 derniers jours : 25

Total : 3,934