Aller au contenu principal

Introduction

If your mixer won't spin or is noisy, follow our guide on how to replace the worm gear.

  1. Using a spudger, gently pry off the aluminum drip ring. Using a spudger, gently pry off the aluminum drip ring.
    • Using a spudger, gently pry off the aluminum drip ring.

  2. Using a 1 mm pin punch and hammer, hammer the pin until it is dislodged from the planetary gear cover.
    • Using a 1 mm pin punch and hammer, hammer the pin until it is dislodged from the planetary gear cover.

  3. Using a spudger, pry the planetary gear cover from the mixer shaft. Using a spudger, pry the planetary gear cover from the mixer shaft.
    • Using a spudger, pry the planetary gear cover from the mixer shaft.

  4. Using a flathead screwdriver, remove the five, 28 mm front motor housing screws.
    • Using a flathead screwdriver, remove the five, 28 mm front motor housing screws.

    • Using the same flathead screwdriver, remove the two, 28 mm locking screws.

    • One of the locking screws contains a safety locking mechanism. Do not interchange these screws with the front motor housing screws.

  5. Turn your device around. Using the same flathead screw driver, remove the two, 28 mm rear locking screws.
    • Turn your device around. Using the same flathead screw driver, remove the two, 28 mm rear locking screws.

    • One of the rear motor housing screws contains a safety locking mechanism. Do not interchange these screws with the front motor housing screws.

  6. Kits pour Apple Watch

    Screen and battery repairs just got easier.

    Acheter maintenant

    Kits pour Apple Watch

    Screen and battery repairs just got easier.

    Acheter maintenant
  7. Using a phillips 2 screwdriver, remove the 10 mm screw from top of back cover. The rear cover is now completely free from the mixer.
    • Using a phillips 2 screwdriver, remove the 10 mm screw from top of back cover.

    • The rear cover is now completely free from the mixer.

  8. Carefully pull the power cord from the notch in back of the mixer. The motor housing cover is now completely free from the base of the mixer.
    • Carefully pull the power cord from the notch in back of the mixer.

    • The motor housing cover is now completely free from the base of the mixer.

  9. Lift the motor housing cover from the mixer base.
    • Lift the motor housing cover from the mixer base.

    • Be sure to place the cover upside down to prevent grease from leaking out.

  10. Using a butter knife or putty knife, remove the grease from the gears. Place the grease in motor housing cover.
    • Using a butter knife or putty knife, remove the grease from the gears.

    • Place the grease in motor housing cover.

  11. Using a Phillips #2 screwdriver, remove the three 20 mm screws from the worm gear tower.
    • Using a Phillips #2 screwdriver, remove the three 20 mm screws from the worm gear tower.

    • The worm gear tower assembly is now free from the mixer base.

  12. Using a pin punch and a hammer, remove the roll pin. Using a pin punch and a hammer, remove the roll pin.
    • Using a pin punch and a hammer, remove the roll pin.

  13. Slide the tower gear out to access the worm gear.
    • Slide the tower gear out to access the worm gear.

  14. Remove the worm gear from the tower.
    • Remove the worm gear from the tower.

Conclusion

To reassemble your device, follow these instructions in reverse order.

25 autre(s) ont terminé cette réparation.

Chris Grant

Membre depuis le 07/10/2014

690 Réputation

1 tutoriel rédigé

Équipe

Cal Poly, Team 14-28, Maness Fall 2014 Membre de l'équipe Cal Poly, Team 14-28, Maness Fall 2014

CPSU-MANESS-F14S14G28

4 membres

12 tutoriels rédigés

13 commentaires

Some corrections:

Step 1 -- Suggest (as the Service Manual does) using a flat-blade screwdriver and tap it with a light hammer to drive the drip ring off.

Step 2 -- the correct size pin punch is 5/32"

Step 3 -- Using two flat-blade screwdrivers, one on each side, pry off the planetary.

A plastic spudger is likely to break. Two points of leverage opposits each other distributes the load and prevents to the planetary and its shaft.

Step 11 -- The proper punch size is 3/32"

Steps 12 & 13 -- There is a washer on each side of the worm gear. Retain these and place one on each side off the grar when reassembling.

A link to the Service Manual:

http://www.kitchenaidparts.eu/documents/...

Finkerbell - Réponse

Cheers Finkerbell,

Very helpful info, as was the main part of the guide.

Not sure what model number I was working on, but when I l lifted off the motor housing, there was still wires connected to the base.

Just be careful at this stage in case you have the same...

markguerin - Réponse

my model K5SS WH is the same as yours until step 5. It doesnt have the two bolts as shown in the picture for step 5 so i wasnt able to complete the repair. any suggestions.

sailsetter - Réponse

Wow! Lovely guide to easy maintenance, no plenty stories

Dennis - Réponse

This is the BEST! Thank you.

Advanamics - Réponse