Introduction

If your device is not turning on it could be because of worn down carbon brushes. Here is a guide to replace these brushes.

Pièces

Aucune pièce nécessaire.

Using a flat head screwdriver, unscrew the brush cap on each side of the mixer by turning them counter clockwise.
  • Using a flat head screwdriver, unscrew the brush cap on each side of the mixer by turning them counter clockwise.

  • Remove brush cap by pulling it toward you.

  • The brushes are held in by springs and will fly out if removed too fast.

Ajouter un commentaire

Remove brush by pulling it toward you.
  • Remove brush by pulling it toward you.

  • One corner of the brush is flattened. You can check which way the brush is oriented by shining a flashlight inside the hole.

Ajouter un commentaire

Conclusion

To reassemble your device, follow these instructions in reverse order.