Ce dont vous avez besoin

  1. Philips Sonicare DiamondClean Spring Replacement, Spring: étape 1, image 1 de 1
    • Pull the toothbrush head off the toothbrush.

  2. Philips Sonicare DiamondClean Spring Replacement: étape 2, image 1 de 1
    • Use a spudger to pry the chrome cap from the base of the toothbrush.

  3. Philips Sonicare DiamondClean Spring Replacement: étape 3, image 1 de 3 Philips Sonicare DiamondClean Spring Replacement: étape 3, image 2 de 3 Philips Sonicare DiamondClean Spring Replacement: étape 3, image 3 de 3
    • Invert the toothbrush and apply pressure against the metal tip until the internals and casing separate.

    • Remove the internals from the casing.

  4. Philips Sonicare DiamondClean Spring Replacement: étape 4, image 1 de 1
    • Remove the rubbers covers from the circuit board and battery.

  5. Philips Sonicare DiamondClean Spring Replacement: étape 5, image 1 de 2 Philips Sonicare DiamondClean Spring Replacement: étape 5, image 2 de 2
    • Separate the upper and lower components by sliding the circuit board section and motor section away from each other.

    • Remove the spring.

Conclusion

To reassemble your device, follow these instructions in reverse order.