Aller au contenu principal

Rug Doctor Spray Button Replacement

Ce dont vous avez besoin

  1. Rug Doctor Spray Button Replacement, Handle: étape 1, image 1 de 1
    • Before you begin disassembly, make sure that the Rug Doctor is not plugged in and that all reservoirs are empty of liquids.

    • Unclip the clear hose from the back of the Rug Doctor.

    Include the part number of the c shaped plate.

    JAMES - Réponse

  2. Rug Doctor Spray Button Replacement: étape 2, image 1 de 2 Rug Doctor Spray Button Replacement: étape 2, image 2 de 2
    • Use a 7/16" (11 mm OK) wrench to hold the handle axle while you use a 7/16" socket to remove the cap nut securing the axle end.

  3. Rug Doctor Spray Button Replacement: étape 3, image 1 de 2 Rug Doctor Spray Button Replacement: étape 3, image 2 de 2
    • Support the handle with one hand. It will be loose after this step.

    • Use fingers or pliers to pull out the handle axle.

    • If the axle feels hard to pull out, squeeze the handle release lever to release pressure on the axle.

  4. Rug Doctor Spray Button Replacement: étape 4, image 1 de 1
    • Detach the handle from the Rug Doctor and set it down.

    • If you need more cable slack, you can set the Rug Doctor on its side.

  5. Rug Doctor Spray Button Replacement, Spray Button: étape 5, image 1 de 2 Rug Doctor Spray Button Replacement, Spray Button: étape 5, image 2 de 2
    • Uncoil the power cable from the handle.

    • Remove the sixteen Phillips fasteners of the following lengths:

    • Six 22.7 mm machine screws

    • Four 35.3 mm machine screws

    • Two 25.2 mm (thicker) machine screws

    • Two 48.4 mm bolts with washers

    • When reinstalling these, the order should be: bolt, washer, handle, washer, 3/8" nut.

    • Two 30.1 mm screws

  6. Rug Doctor Spray Button Replacement: étape 6, image 1 de 2 Rug Doctor Spray Button Replacement: étape 6, image 2 de 2
    • Separate the bottom edge of the handle slightly until the spring-loaded plunger pops out of its socket.

  7. Rug Doctor Spray Button Replacement: étape 7, image 1 de 3 Rug Doctor Spray Button Replacement: étape 7, image 2 de 3 Rug Doctor Spray Button Replacement: étape 7, image 3 de 3
    • Re-assembly tip—Follow this step to re-seat the plunger.

    • Use your fingers to push the black plunger down towards the bottom of the handle into position. This may take significant force.

    • Once the plunger slips into position, squeeze the the two handle halves together.

    • If done correctly, the handle should close tightly without a gap and lock the plunger in place.

    • If that doesn't happen, check to see if the plunger is properly positioned, and that no wires are pinched.

    • Continue squeezing the two handle halves together while you reinstall the handle's lower screws.

  8. Rug Doctor Spray Button Replacement: étape 8, image 1 de 2 Rug Doctor Spray Button Replacement: étape 8, image 2 de 2
    • Remove the two 11.4 mm long Phillips screws holding the cover plate on the handle.

    • Remove the cover plate.

  9. Rug Doctor Spray Button Replacement: étape 9, image 1 de 3 Rug Doctor Spray Button Replacement: étape 9, image 2 de 3 Rug Doctor Spray Button Replacement: étape 9, image 3 de 3
    • Use a pair of pliers to grasp the lip of the screw post close to the handle release lever.

    • While gripping the screw post, use a large flathead screwdriver to remove the machine screw mated to the other end of the screw post.

    when removing these for the first time you may find it hard to grasp one end and unscrew the other side. i ended up cutting one of the heads to get it off. locktite used was green, and just replaced with new screw post without using same locktite.

    LUIS - Réponse

    Just order Rug Doctor Complete Handle 12672 for the whole hadle assembly. This is not worth the time trying to get it off. Using taps, drill bits, vices, anything to try and hold the bald headed side stationary will still cause it to slip, and on the flat head side the channal isnt deep enough for the screw drivers causing it to easily slip and strip the head.

    ERIC - Réponse

    One way to remove the 'carriage' type fastener, is to take a Dremel and notch a slot like for a standard screwdriver. I've been fairly successful in using this workaround.

    JERRY - Réponse

  10. Rug Doctor Spray Button Replacement: étape 10, image 1 de 2 Rug Doctor Spray Button Replacement: étape 10, image 2 de 2
    • Pull the two handle halves apart.

  11. Rug Doctor Spray Button Replacement: étape 11, image 1 de 2 Rug Doctor Spray Button Replacement: étape 11, image 2 de 2
    • Re-assembly tip—Before you close the handle, check the following:

    • The lever mechanism components are properly stacked and oriented as shown.

    • Both brass bushings are in their sockets.

  12. Rug Doctor Spray Button Replacement: étape 12, image 1 de 3 Rug Doctor Spray Button Replacement: étape 12, image 2 de 3 Rug Doctor Spray Button Replacement: étape 12, image 3 de 3
    • Note how the switch is wired:

    • Red and black wires on the top sockets (order does not matter)

    • Two white wires on the bottom sockets

    • Use fingers or pliers to wiggle and pull the four connectors from the switch module.

  13. Rug Doctor Spray Button Replacement: étape 13, image 1 de 3 Rug Doctor Spray Button Replacement: étape 13, image 2 de 3 Rug Doctor Spray Button Replacement: étape 13, image 3 de 3
    • Use fingers or wide pliers to squeeze the black retainer tabs on each side of the button module.

    • While squeezing, wiggle and push the button module out of the front of the handle.

    • Remove the button module.

    • To install a replacement button, push the button in through the top of the handle until it clicks in place. It should not be loose or easily budged.

    This is a terrible idea. The easy way would be to use a small flat head screw driver to pry out the switch. See where the wires go. There are two white wires on one side and a black and a red ones that go on the other. Replace the wires and fit the new switch in it's place. That's it. However, usually the wires are really short and it may be hard to get them out enough to fit them on the new one. In this case you will need to undo the strain relief at the bottom of the handle and feed it up into opening. That is the easy way out.

    Abdul Satar Janmohamed - Réponse

Conclusion

To reassemble your device, follow these instructions in reverse order while noting the re-assembly tips.

11 autres ont terminé cette réparation.

Arthur Shi

Membre depuis le 01/03/18

248 412 Réputation

503 tutoriels rédigés

Équipe

iFixit Membre de l'équipe iFixit

Staff

136 membres

16 566 tutoriels rédigés

3 commentaires

Remove the power cables strain relief at the handle for slack, not the 16 screws to split the handle. That takes all day and one time you will lose a screw or 2 or 4.

NICHOLAS - Réponse

could not use pliers, label was as thick as face on head, will end up replacing whole handle assembly, bad choice for fastener

JOSEPH - Réponse

cut a notch in the fastener with a dremel to get out the handle bolt

JEREMY - Réponse

Ajouter un commentaire

Nombre de vues :

Dernières 24 heures : 2

7 derniers jours : 22

30 derniers jours : 58

Total : 5,390