Aller au contenu principal

Sigma 24-70 Disassembly

Ce dont vous avez besoin

  1. Sigma 24-70 Disassembly, Sigma 24-70 Disassembly: étape 1, image 1 de 1
    • 1°/ Remove the 4 screws at the bottom (take care because to one of them, blue screw, is shorter than the others)

  2. Sigma 24-70 Disassembly: étape 2, image 1 de 2 Sigma 24-70 Disassembly: étape 2, image 2 de 2
    • Remove the 4 screws around the steel ring in order to disassemble the captor (blue area) and the plastic ring (red area) which is insert inside the steel ring and behind the captor

  3. Sigma 24-70 Disassembly: étape 3, image 1 de 1
    • Remove the steel ring (red area) due to a vertical translation (take care with the vertical sheet, in green area metal, which is used to open the diaphragm)

Conclusion

To reassemble your device, follow these instructions in reverse order.

8 autres ont terminé cette réparation.

Greg

Membre depuis le 12/10/12

357 Réputation

1 tutoriel rédigé

0 commentaires

Ajouter un commentaire

Nombre de vues :

Dernières 24 heures : 0

7 derniers jours : 7

30 derniers jours : 23

Total : 3,151