Aller au contenu principal

Introduction

The boiler heat the water to the needed temperature for both the steam wand and portafilter. If your machine isn't heating up, one possible cause is a failed heating element inside the boiler. This guide will show you how to test for this.

Pièces

Aucune pièce spécifiée.

  1. Remove the 6 Phillips #1 screws from the back panel. Remove the back panel.
    • Remove the 6 Phillips #1 screws from the back panel.

    • Remove the back panel.

  2. Fix Kits pour batterie de MacBook

    À partir de $69.99

    Buy Now

    Fix Kits pour batterie de MacBook

    À partir de $69.99

    Buy Now
  3. Make sure the machine is turned off and unplugged.
    • Make sure the machine is turned off and unplugged.

    • Set your voltmeter in continuity mode and place the leads on the two 90 degree prongs on the boiler's heating element.

    • It does not matter which lead touches which prong as you're just testing for a break, or "open" in the heating element circuit.'''

    • If the voltmeter shows 0, or "open", then there is an issue with the heating element's continuity and it needs to be replaced.

    • If given a reading, then your heating element is fine.

  4. In the water reservoir, place mixture of de-calcifying agent and water as directed on the product label.
    • In the water reservoir, place mixture of de-calcifying agent and water as directed on the product label.

    • Place a cup, to catch fluid, underneath the portafilter.

    • Run Barista, as if making coffee, for the amount of time directed by the de-calcifying product.

    • See the links section of the device page for further directions.

Conclusion

To reassemble your device, follow these instructions in reverse order.

8 autre(s) ont terminé cette réparation.

Brian McMurray

Membre depuis le 31/01/2011

198 Réputation

1 tutoriel rédigé

Équipe

Cal Poly, Team 4-42, Regan Winter 2011 Membre de l'équipe Cal Poly, Team 4-42, Regan Winter 2011

CPSU-REGAN-W11S4G42

4 membres

5 tutoriels rédigés

I did this a few months ago and the boiler was full of rusty gunk. This guide sure did help me out.

oguitar200 - Réponse

the same here - it was disgusting... was afraid to have damaged it while cleaning it. tested it yesterday already... just going through all the steps to validate function of the units.

Martin Zeitler -

hi ! we have Starbucks Barisa Milano. some how it didnt want switch on! my husband wanted to have a look but we cant open. do you gave any guidence?

Zorigoo Purev - Réponse

Ajouter un commentaire

Voir les statistiques:

Dernières 24 heures : 0

7 derniers jours : 12

30 derniers jours : 69

Total : 17,231