[title] Securing the Sensor
[* light_blue] Place the Sontek IQ sensor in the water facing the direction of flow.
[* icon_note] There is an arrow on the sensor itself showing which way water should flow.
[* orange] Secure the sensor to the steel strut with 1/2" bolts, washers, and strut nuts. Fasten with a 1/2" wrench.
+[* icon_note] The sensor can also be secured to the steel strut channel using only the L bracket and offset on the sensor instead of the aluminum strut channel