Run diode mode measurement of capacitors around the moldy IC U3400, Nothing goes wrong.
Fault Confirming
  • Run diode mode measurement of capacitors around the moldy IC U3400, Nothing goes wrong.

  • Continue to run diode mode measurement of the third space PCB. The measured value of Pin S30 is 40, which is abnormal.

  • Since Pin S30 is connected directly to Pin L4 of U3400, the fault is probably related to U3400. So the next thing we do is to check U3400.

  • Remove U3400 with Hot Air Gun. We can see that U3400 and its bonding pad have mildewed severely.