Traduction de l’étape 2

Étape 2
Run diode mode measurement of the Tele camera connector J4000. The measured value of Pin 25 is OL, which is abnormal.
Diagonosis
  • Run diode mode measurement of the Tele camera connector J4000. The measured value of Pin 25 is OL, which is abnormal.

  • The first thing we do is to check the zero-ohm resistor R4006 on Pin 25 relevant circuit. Nothing goes wrong.

  • We can confirm that the fault is probably related to U3700, the camera power supply IC on the circuit.

  • Let's try to replace with a new IC.