Aller au contenu principal

Cómo solucionar el error C6 en una olla a presión

Anglais
Espagnol

Traduction de l’étape 6

Étape 6
  • In its resting state, the pressure sensor should be continuous, which means the meter should read almost zero resistance.

  • If the meter shows a high resistance or no continuity, it could mean that the sensor contacts are dirty. Double-check your meter contacts and make sure they're grasping onto the wires.

  • Use a spudger or your finger to firmly press on the top of the sensor until it clicks.

  • The meter should change to show no continuity (0.L, in my meter's case). If it doesn't, there is a potential electrical short—the contacts may be fused, or you may need to replace the sensor.

En estado de reposo, el sensor de presión debe presentar continuidad, lo que significa que el medidor debe indicar una resistencia casi nula.

Si el medidor muestra una resistencia alta o no hay continuidad, podría significar que los contactos del sensor están sucios. Vuelve a comprobar los contactos del medidor y asegúrate de que estén sujetos a los cables.

Utiliza un spudger o tu dedo para presionar firmemente la parte superior del sensor hasta que haga clic.

El medidor debería cambiar para mostrar que no hay continuidad (0,L, en el caso de mi medidor). Si no es así, puede que haya un cortocircuito: los contactos pueden estar fundidos o puede que tengas que cambiar el sensor.

Vos contributions sont faites dans le cadre de la licence open source Creative Commons.