Aller au contenu principal

Popular clothes dryer series by Kenmore.

60 questions Voir tout

Can a blown Cutoff fuse keep my dryer from starting

Changed thermal fuse and fixed heater coil that was grounded. It blew the timer which I also fixed and have Continuity everywhere except the cutoff fuse. It still won’t start. Is this why are is it Control panel issues?

Update (09/29/2020)

Roper mod# red4640YQ1

Répondu ! Afficher la réponse J'ai le même problème

Cette question est-elle utile ?

Indice 0
4 commentaires

It’s an older Roper model

par

I’ll get a better description if you need when I get off this afternoon

par

Thank you I really appreciate it!!

par

Update: the fuse was changed and dryer is running.... but now it just starts before pressing the start switch!!! Any suggestions?

par

Ajouter un commentaire

1 Réponse

Solution retenue

What exact model is this? We need to know that in order to try and look at the schematic and yes a bad cutoff can be the issue, but there may be more going on here.

Update (10/01/2020)

Ben Lewis, I can confirm that if the fuse is bad the dryer won't start or will run but not heat. So I would suggest to start with the fuse.

Cette réponse est-elle utile ?

Indice 1

1 commentaire:

I posted in the old comments didn’t know if you would see it but the fuse worked but now when I put it on a cycle it just starts up before pressing start switch

par

Ajouter un commentaire

Ajouter une réponse

Ben Lewis sera éternellement reconnaissant.
Nombre de vues :

Dernières 24 heures : 1

7 derniers jours : 2

30 derniers jours : 5

Total : 104