Aller au contenu principal

This is an older equipment line from Saeco. All are labeled Sup 018. (Badge on the bottom). They were later sold under the name Spidem Trevi

13 questions Voir tout

Saeco Vienna grinds beans but doesn't stop grinding or proceed to brew

First my Saeco is NOT a Sup 018, just a Vienna probably because it is 20+ yrs old. I have determined the grounds are not being dumped from the collector into the brew group because the solenoid is not being activated. However I do not know whether the solenoid is bad or whatever determines there are enough grounds has failed.

What triggers the 'dump-the-shot' action?? is my basic question.

Répondre à cette question J'ai le même problème

Cette question est-elle utile ?

Indice 0
Ajouter un commentaire

2 Réponses

There is a microswitch that sends a signal to the circuit board which starts the doser solenoid and the brewing cycle. Could just require dismantling and cleaning or new switch. Worst case new circuit board. Unlikely it is the solenoid Most likely needs cleaning.

Cette réponse est-elle utile ?

Indice 0
Ajouter un commentaire

Google for "Saeco Vienna Testmode". This will help determining the issue, e.g. this video. I see two possibilities: the microswitch of the grind chamber, as mentioned above, hopefully a cleaning ist sufficient, maybe a replacement of the switch. You will find the chamber following the outlet of the ginder.

Or worse: a faulty PCB, in this case a replacement is an option. Much cheaper is the replacement of some parts on the PCB, there are repairkits. Good luck!

Cette réponse est-elle utile ?

Indice 0
Ajouter un commentaire

Ajouter une réponse

Ken Sharples sera éternellement reconnaissant.
Nombre de vues :

Dernières 24 heures : 0

7 derniers jours : 3

30 derniers jours : 5

Total : 74