Introduction

Use for a diagnosed wiring problem.

Pièces

Aucune pièce nécessaire.

  1. Remove the backplate.
    • Remove the backplate.

    • Using a Torx T20 screwdriver, remove the four screws attaching the back plate.

  2. Remove the drill handle.
    • Remove the drill handle.

    • Using the Phillips #2 screwdriver, remove the five screws attaching the drill handle to the body.

    • Remove the gear casing from the body.

    • Using the Philips #2 screwdriver, remove the four screws attaching the gear casing to the body.

    • Use a multimeter set above 18V DC to check electrical connections where wires meet drill, switch, or battery terminal.

    • Look for corrosion or burnt wires.

    • If there are any bad connections or if there is visible damage, replace damaged wire and solder.

    • After soldering sand off jaged solder then wrap with electrical tape

Conclusion

To reassemble your device, follow these instructions in reverse order.