Introduction

For this procedure you will have to first remove the upper case using the Gamebit. Afterwards you will need to remove the metal bar attaching the eject button to the system. Be careful not to loose the spring when you remove the bar. These steps will only require the Gamebit.

Pièces

Aucune pièce nécessaire.

  1. Remove the six screws located on the underside of the system using the Gamebit 4.5mm screwdriver.
    • Remove the six screws located on the underside of the system using the Gamebit 4.5mm screwdriver.

    In order to prevent damage to the fuse, make sure that you always cycle the power before doing so with the power supply disconnected.

    Raucedine - Réponse

    There is a step missing from these instructions. There are two philips head screws where the AV/Power ports are on the back of the motherboard that need to be removed before you can remove the motherboard itself.

    phoenixknight8082 - Réponse

    I replaced my controller port, thinking that it was the culprit, but my SNES is still having issues. Nothing works for controller port 1 and only a few buttons work for controller port 2. I tried switching out the controllers and the issue seems to be isolated to the SNES itself. Does anyone have any other suggestions for fixing my issue?

    Thanks in advance.

    Mike Watts - Réponse

    For those facing a black screen on startup (after having cleaned pins on cartridges and cartridge slot) WITH power light coming on, turn off console, remove power, and try shorting out the capacitor leads. My SNES stopped working suddenly after a single power cycle, and shorting out the leads (while UNPOWERED) revived it.

    Austin Barnett - Réponse

    Could you further explain how to short the capacitor leads?

    Will Pulman -

  2. Carefully flip the unit back over.
    • Carefully flip the unit back over.

    • Locate the seam. Lift and separate the upper half of the case from the lower half of the case.

    Ajouter un commentaire

    • Lift the right side of the eject lever out of the housing.

    Ajouter un commentaire

    • Pull the metal bar out through the right side of the eject lever.

    • Make sure to keep track of the spring located on the left side of the lever as it may shoot off when removing the metal bar.

    • When reassembling, the procedure becomes more difficult due to the spring (marked red). We recommend that one person hold the spring in place (picture 3) while another person slides the metal bar back into the left housing, and slide the eject lever onto the metal bar.

    Ajouter un commentaire

Conclusion

To reassemble your device, follow the instructions in reverse order.

5 autre(s) ont terminé cette réparation.

James Shirley

Membre depuis le 03/10/2010

721 Réputation

2 tutoriels rédigés

Équipe

Cal Poly, Team 4-47, Amido Fall 2010 Membre de l'équipe Cal Poly, Team 4-47, Amido Fall 2010

CPSU-AMIDO-F10S4G47

4 membres

10 tutoriels rédigés

Ajouter un commentaire

Voir les statistiques:

Dernières 24 heures : 2

7 derniers jours : 12

30 derniers jours : 54

Total : 11,557