+ | [page_title|Ohmeda 7000 Ventilator] |
---|
+ | |
---|
+ | == ***Background*** == |
---|
+ | |
---|
+ | The Ohmeda 7000 ventilator is an anesthesia ventilator that is pneumatically driven is electronically controlled. |
---|
+ | |
---|
+ | Before the company was named Ohmeda in 1984, they were formerly known as the Ohio Chemical and Manufacturing Company that was founded in 1910 |
---|
+ | |
---|
+ | The Ohmeda 7000 was established in 1995 |
---|
+ | |
---|
+ | Some of the features of the Ohmeda 7000 include the following: |
---|
+ | |
---|
+ | * Separate from the driving gas circuit is the patient circuit |
---|
+ | * Included is a metal bellows assembly that can be sterilized |
---|
+ | * Controls for the operator to use, with linearly calibrated scales |
---|
+ | * The Ohmeda 7000 is compatible with both pediatric and adult bellows |
---|
+ | * The Ohmeda 7000 has audible alarms as well as visual alarms that inform the operator that there are abnormal conditions |
---|
+ | |
---|
+ | == ***Identification*** == |
---|
+ | |
---|
+ | * Height: 14.3 inches (36.3 cm) |
---|
+ | * Width: 8.7 (22.1 cm) |
---|
+ | * Depth: 9.2 inches (9.2 cm) |
---|
+ | * Weight – 8.5 kg / 19 lbs |
---|
+ | * Voltage - User selectable: 100, 120, 220 or 240 VAC ±10% (50/60 Hz) |
---|
+ | * Power Consumption - 53 watts maximum |
---|
+ | * Respiratory Range - 6 - 40 B/min |
---|
+ | * I:E Ratio - 1:1 to 1:3 |
---|
+ | * Tidal Volume – Adult bellows: 100 -1600 mL; Pediatric bellows: 0 to 300 mL |
---|
+ | * Inspiratory Flow Rate - 4 to 62 L/min |
---|
+ | * Alarm Types - Ventilator failure, Set Volume Not Delivered, Low Oxygen Supply Pressure, Low Airway Pressure, Actual I:E less than dial setting |
---|
+ | * This device does not come in more than one color |
---|
+ | |
---|
+ | == Technical Specification == |
---|
+ | |
---|
+ | * Voltage - User selectable: 100, 120, 220 or 240 VAC ±10% (50/60 Hz) |
---|
+ | * Power Consumption - 53 watts maximum |
---|
+ | * Calibrated electronic control allows for a more accurate ventilation delivery |
---|
+ | * Minute volume, I:E ration and rate controls can adjust without affecting other settings |
---|
+ | * Comprehensive alarms and safety features |
---|
+ | * Accommodates nearly any patient size |
---|
+ | |
---|
+ | == Sources == |
---|
+ | |
---|
+ | https://www.woodlibrarymuseum.org/museum/ohio-modulus/ |
---|
+ | |
---|
+ | https://pubs.asahq.org/anesthesiology/article/96/3/766/39913/Ventilatory-Failures-with-the-Datex-Ohmeda-7900 |
---|
+ | |
---|
+ | https://avantehs.com/p/ohmeda-7000-anesthesia-ventilator/113 |
---|
+ | |
---|
+ | file:///Users/ashlynn.garcia/Downloads/Ventilator%207000%20Operation%20and%20Maint%20(4).pdf |
---|
+ | |
---|
+ | * ''The last fourth document and the fifth document are failures that occurred with the Ohmeda 7000 Ventilator, this article explains what happened and what went wrong/was wrong with the medical device'' |
---|
+ | |
---|
+ | [video|https://www.youtube.com/watch?v=XUYEzFgrxIA] |
---|
+ | |
---|
+ | The video is not in English, however, you can see how the Ohmeda 7000 Ventilator is meant to be used |
---|
+ | |
---|