Dell PowerEdge R310 and R410 Cable Routing Procedures

Technical reference 12 pages · 1.29 MB · PDF

Cable Routing Procedures for Dell $ ^{™} $ PowerEdge $ ^{™} $ R310 & R410 Systems

By Greg Henderson, Riyadh Moe, Chris Kitten and Jose L. Flores

Dell™ | Datacenter Infrastructure Engineering

June 2010

Image

DELL

THIS WHITE PAPER IS FOR INFORMATIONAL PURPOSES ONLY, AND MAY CONTAIN TYPOGRAPHICAL ERRORS AND TECHNICAL INACCURACIES. THE CONTENT IS PROVIDED AS IS, WITHOUT EXPRESS OR IMPLIED WARRANTIES OF ANY KIND.

© 2010 Dell Inc. All rights reserved. Reproduction of this material in any manner whatsoever without the express written permission of Dell Inc. is strictly forbidden. For more information, contact Dell.

Dell, the DELL logo, the DELL badge, and PowerEdge are trademarks of Dell Inc.

Cable Routing Procedures for Dell™ PowerEdge™ R310 & R410 Systems

Contents

Introduction ..... 2
Section 1: Cabling a Dell™ PowerEdge™ R310 or R410 With a Cable Management Arm (CMA) ..... 2
1.1 Connecting the CMA Cables to the System ..... 2
1.2 Installing the Inner CMA Attachment Bracket ..... 3
1.3 Routing the Power Cables Through the Strain Reliefs ..... 3
1.4 Routing the Cables Through the CMA ..... 3
1.5 Left-Side Mounting Instructions ..... 4
1.6 Right-Side Mounting Instructions ..... 6
Section 2: Cabling a Dell™ PowerEdge™ R310 or R410 System Without a CMA ..... 7
2.1 Routing the Cables ..... 7
2.2 Removing the CMA Brackets for Shallow Racks ..... 7
Section 3: Replacing a Power Supply on a PowerEdge™ R310 or R410 System With a CMA ..... 8
Section 4: Cabling a PowerEdge™ R310 or R410 System Installed in Static Rails ..... 9

Table of Figures

Figure 1: System with Cables Installed ..... 2
Figure 2: Attaching the Inner CMA Attachment Bracket ..... 3
Figure 3: Routing Power Cables Through the Strain Reliefs ..... 3
Figure 4: Routing the Cables Through the CMA ..... 4
Figure 5: Attaching the KVM Dongle to the CMA Basket ..... 5
Figure 6: Left-Side Mounted CMA Installation ..... 6
Figure 7: Right-Side Mounted CMA Installation ..... 6
Figure 8: Cable Routing Without a CMA ..... 7
Figure 9: Removing the CMA Brackets for Shallow Racks ..... 8
Figure 10: Disconnecting the Inner CMA Attachment Bracket ..... 9
Figure 11: Replacing the Outer Power Supply ..... 9
Figure 12: Cabling a System Installed in Static Rails ..... 10

Cable Routing Procedures for Dell™ PowerEdge™ R310 & R410 Systems

Introduction

This white paper covers recommended cable routing procedures for Dell $ ^{™} $ PowerEdge $ ^{™} $ R310 & R410 systems in the following racks:

• PowerEdge™ 4210/2410

• PowerEdge $ ^{TM} $ 4820/4220/2420

If you are using the optional CMA, following these procedures will allow you to extend the system from the rack for service without powering down or disconnecting the cables. If you are not using the CMA, following these procedures will ensure secure attachment and strain relief of the cables behind the system. For guidelines on how to route cables within the rack, refer to the Dell Best Practices Guide for Rack Enclosure white paper.

Section 1: Cabling a Dell $ ^{TM} $ PowerEdge $ ^{TM} $ R310 or R410 With a Cable Management Arm (CMA)

This section details how to cable a PowerEdge™ R310 or R410 system using a CMA. If you are cabling the system without the optional CMA, refer to Section 2.

Follow the instructions contained in the Rack Installation Guide in the rail kit to install the server into the rack. Once installed, use these instructions to install the cables. All illustrations in the following sections were created using a PowerEdge™ R410 system.

NOTE: PowerEdge™ R310 & R410 systems are not compatible with previous generation rails and CMAs.

1.1 Connecting the CMA Cables to the System

Attach the CMA tray to the back of the rails as described in the CMA Installation Instructions provided in the CMA kit. Connect all applicable cables to the rear of the system and verify that all connections are secure. See Figure 1.

Figure 1: System with Cables Installed

Image

1.2 Installing the Inner CMA Attachment Bracket

As described in the Rack Installation Instructions, locate and attach the appropriate inner CMA attachment bracket based on which side you wish to mount the CMA. Use the bracket marked "A" for mounting the CMA on the left side, and the bracket marked "B" for mounting on the right side. See Figure 2.

Figure 2: Attaching the Inner CMA Attachment Bracket

Image

1.3 Routing the Power Cables Through the Strain Reliefs

After you have installed the tray and cables, route the power cables through the strain reliefs