Why won’t my ac cycle?

The compressor runs continuously even when turned off and is not cycling. Any solutions?

Répondre à cette question J'ai le même problème

Cette question est-elle utile ?

Indice 0
Ajouter un commentaire

1 Réponse

Hi @davidkurtz75410

Is it only the compressor motor that continues to run or the AC fan as well?

Looking at the wiring diagram for an LRA08PZU1* series AC unit (see image below), it appears that a relay is used to control the power to compressor and the fan, although the fan seems to have speed control so it may be able to be turned off.

Perhaps there's a sticking or faulty relay contact on the control board.

Block Image

(click on image)