Étape 10
Philips Sonicare DiamondClean HX9340 Battery Replacement: étape 0, image 1 de 3 Philips Sonicare DiamondClean HX9340 Battery Replacement: étape 0, image 2 de 3 Philips Sonicare DiamondClean HX9340 Battery Replacement: étape 0, image 3 de 3
  • Apply flux to the positive contact of the battery on the PCB (Incidental finding is a SMD fuse F1 on this PCB)

  • Using desoldering braid unsolder the positive contact from the PCB.

  • Apply some gentle pressure with a small tool to remove the battery.

  • The battery should remove easily. If it does not, double check the battery contacts on the PCB to ensure they are not still connected somewhere. Another going over with the soldering iron may be required to complete that task.

Appliquez du flux au contact positif de la batterie sur le PCB (nous découvrons au passage sur ce PCB un fusible CMS F1).

En utilisant une tresse à dessouder, dessoudez le contact positif du PCB.

Appliquez une légère pression avec un petit outil pour retirer la batterie.

La batterie doit se retirer facilement. Si ce n'est pas le cas, vérifiez les contacts de la batterie sur le PCB pour vous assurer qu'ils ne sont pas encore connectés quelque part. Un autre passage avec le fer à souder peut être nécessaire pour terminer cette tâche.