Hi @cristianan
If it only displays OL when in the Volts or Continuity measuring ranges and not when selecting other functions such as capacitance or current then as you say the meter has a fault with these two functions.
You say that “I have written them a bunch of times and to voltcraft but to no avail... “.
I’m not sure if you mean that you just wanted to get technical advice from them or not but as there is a 3 year Voltcraft manufacturer’s warranty on the meter and if the warranty period is still valid I suggest that you contact Conrad about claiming a manufacturer’s warranty repair or replacement.
If I am reading it correctly there is also a 2 year guarantee by Conrad on their “electronic items” so you should be covered either way if the meter is less than 2 years old.
Cette réponse est-elle utile ?
A voté
Annuler
Indice
1
9 commentaires
It seems to say OL and need power cycle even with no probes attached or both probes attached - even when connected to each other or the same wire.
is there anything I can try ?
par Cristian
Hi @cristianan ,
What is the make and model number of the meter?
par jayeff
Hi @jayeff
It’s a Voltcraft R-200 I purchased from Conrad Electronic
I have written them a bunch of times and to voltcraft but to no avail...
par Cristian
OL does not mean "Over Load", it means "Open Loop". The meter is fine, it is an open circuit, meaning it has no voltage to measure.l
par ronscott64
when I make lighting cable megger test display show OL, what does mean OL?
par hantunmaung85