Anglais
Français

Traduction de l’étape 5

Étape 5
To complete your continuity test, place one probe at each end of the circuit or component you want to test. As before, if your circuit is continuous, the screen displays a value of zero (or near zero), and the multimeter beeps.
  • To complete your continuity test, place one probe at each end of the circuit or component you want to test.

  • As before, if your circuit is continuous, the screen displays a value of zero (or near zero), and the multimeter beeps.

  • If the screen displays 1 or OL (open loop), there's no continuity—that is, there's no path for electric current to flow from one probe to the other.

  • Continuity is non-directional, meaning it doesn't matter which probe goes where. But there are exceptions—for instance, if there's a diode in your circuit. A diode is like a one-way valve for electricity, meaning it will show continuity in one direction, but not in the other.

Pour compléter votre test de continuité, placez une sonde à chaque extrémité du circuit ou du composant à tester.

Comme précédemment, si le circuit est continu, l'écran affiche une valeur 0 (ou approximativement) et le multimètre "bip".

Si l'écran affiche 1 ou OL (circuit ouvert), il n'y a pas de continuité—c'est à dire, le courant électrique ne peut pas circuler d'une sonde à une autre.

La continuité n'est pas directionnelle, peu importe quelle sonde se place où. Mais il existe des exceptions, par exemple, s'il y a une diode dans votre circuit. Une diode est comme une vanne unidirectionnelle pour l'électricité, ce qui signifie qu'elle conduira l'électricité dans une direction, mais pas dans l'autre.