-[* black] Use an insulated screwdriver to discharge the capacitor. You do this by:
+[* icon_caution] ***Caution***: Hazardous situation which can result in minor or moderate injury. Use an insulated screwdriver to discharge the capacitor. You do this by:
[* black] The terminals should have stamps on the metal that tell you which terminal is which. One is labeled "C" for "common," the next is labeled "Fan," and the last one is labeled "Hum" for the compressor.
[* black] Use the screwdriver to bridge the gap between the terminals labeled "Hum" (Compressor) and "common" (ground). This will discharge any stored electricity in the capacitor to prevent any damage to your electric meter.
[* black] Repeat this step with the fan terminal and the common terminal.