Aller au contenu principal

Philips Sonicare DiamondClean HX9340 Akku austauschen

Anglais
Allemand

Traduction de l’étape 10

Étape 10
Philips Sonicare DiamondClean HX9340 Battery Replacement: étape 0, image 1 de 3 Philips Sonicare DiamondClean HX9340 Battery Replacement: étape 0, image 2 de 3 Philips Sonicare DiamondClean HX9340 Battery Replacement: étape 0, image 3 de 3
  • Apply flux to the positive contact of the battery on the PCB (Incidental finding is a SMD fuse F1 on this PCB)

  • Using desoldering braid unsolder the positive contact from the PCB.

  • Apply some gentle pressure with a small tool to remove the battery.

  • The battery should remove easily. If it does not, double check the battery contacts on the PCB to ensure they are not still connected somewhere. Another going over with the soldering iron may be required to complete that task.

Gib etwas Flussmittel auf den Plus Akkuanschluss auf der Platine. (Ein Zufallsfund ist die SMD Sicherung F1 auf der Platine).

Entlöte den Plus Akkuanschluss auf der Platine mit Hilfe von Entlötlitze.

Drücke den Akku mit einem kleinen Werkzeug vorsichtig heraus.

Der Akku sollte sich leicht entfernen lassen. Wenn nicht, solltest du nochmals die Akkuanschlüsse auf der Platine darauf überprüfen, ob sie immer noch verbunden sind. Eventuell ist nochmals ein Durchgang mit dem Lötkolben nötig.

Vos contributions sont faites dans le cadre de la licence open source Creative Commons.