Pentax Spotmatic Light Meter Calibration

Traduction de l’étape 4

Anglais
Français
Étape 4
Pentax Spotmatic Light Meter Calibration, Make adjustments: étape 0, image 1 de 2 Pentax Spotmatic Light Meter Calibration, Make adjustments: étape 0, image 2 de 2
Make adjustments
  • Use a pick to adjust the variable resistor through the opening in the top plate.

  • Turn it until the needle in the viewfinder is centered in the opening, indicating a proper exposure.

  • The adjustment resistor shown with the top cover removed.

  • Repeat steps 3 and 4 for several different light levels.

  • Since the Spotmatic only has one adjustment resistor, it may not be possible to center the needle at every light level. Make compromises as necessary.